Charge Station Configuration

Configuring Charge Stations for Smart Charging

This guide will help you set up your charge stations correctly for smart charging functionality.

Prerequisites

  • Make sure you have the latest firmware installed on your charge station

Configuration Steps

1. Basic Requirements

Before beginning the configuration process, verify these essential conditions:

  • Ensure your charge station is connected via OCPP 1.6
  • Deactivate any local load balancing functionality on the charge station

2. Configuration Parameters

Set the following parameters based on your charge station type:

AC Charge Stations
  • MeterValueSampleInterval: Set to 300
  • MeterValuesSampledData: Must include either:
    • Energy.Active.Import.Register,Current.Import,Current.Offered
    • Energy.Active.Import.Register,Current.Import.L1,Current.Import.L2,Current.Import.L3,Current.Offered
DC Charge Stations
  • MeterValueSampleInterval: Set to 30
  • MeterValuesSampledData: Must include:
    • Energy.Active.Import.Register,Power.Active.Import,Power.Offered
⚠️ Important: Some charge station vendors require specific settings for smart charging to work properly. Please check: link

Troubleshooting

If you encounter issues or need to test a new charge station:

  • Integration testing takes approximately one hour for new charge stations
  • Keep firmware updated to ensure compatibility
Note: Do not add untested charge stations to a smart charging group as proper functioning cannot be guaranteed.

Next step: link