How is Charge Station, Connector and EVSE status determined?

Charge Station Status

Charge station status comes from the OCPP StatusNotification message where connectorId = 0, as per OCPP this is the charger level status. This is then mapped from OCPP to OCPI.

EVSE Status

EVSE status is derived from the Connector Statuses, since we don’t actually receive a status for an Evse in OCPP.

The status of an EVSE is derived by taking the highest value status of all of its connectors.

Priority list (top is lowest value)

Unknown

Faulted

Unavailable

Available

Reserved

Preparing

Finishing

SuspendedEVSE

SuspendedEV

Occupied

Charging

Connector Status

Connector status is OCPPStatusNotification messages where connectorId > 0 (i.e. connector level). The OCPP is mapped to ocpi.

OCPP to OCPI Status Mapping

Below table shows the OCPP to OCPI Status mapping

OCPP Status
OCPI Status
Available
AVAILABLE
Preparing
AVAILABLE
Charging
CHARGING
Occupied
CHARGING
SuspendedEVSE
CHARGING
SuspendedEV
CHARGING
Finishing
CHARGING
Reserved
RESERVED
Unavailable
OUTOFORDER
Faulted
OUTOFORDER
Unknown
UNKNOWN
UNKNOWN