Meter Values
The Meter Values are the readings from the Charge Station from a number of properties.
For more information and navigation on Diagnostics in general, please visit this article: Charge Station Diagnostics page
Main use cases:
- Understand whether the Charge Station is sending Meter Values at all (no meter values would not update e.g. Apps for ongoing session information)
- Smart Charging diagnostics
- Charging speed by comparing difference between two Meter Values
Analyzing MeterValues
Hovering over the Payload will show the Meter Value payload.
Key components are:
- Timestamp
- Value
Meter Value 'value types'
As specified by OCPP, there can be various Units sent along a Meter Value, however there are 4 common ones:
- Energy (Wh or kWh)
- Amperes
- Volts
- Temperature
Multi-Phase meter Values
If a Charge Station has 3 phases, it will send four Meter Values, one for each phase and the cumulative of the Charge Station:
Meter Value Measurands
OCPP defines different measurands that can be passed on through meter values.
The key value in most cases is the Energy.Active.Import.Register or simply 'Energy (consumed)" as represented in the EvPortal.
Value Description | Description | Used in GFX |
Current.Export | Instantaneous current flow from EV | |
Current.Import | Instantaneous current flow to EV | Yes |
Current.Offered | Maximum current offered to EV | |
Energy.Active.Export.Register | Energy exported by EV (Wh or kWh) | |
Energy.Active.Import.Register | Energy imported by EV (Wh or kWh) | Yes |
Energy.Reactive.Export.Register | Reactive energy exported by EV (varh or kvarh) | |
Energy.Reactive.Import.Register | Reactive energy imported by EV (varh or kvarh) | |
Energy.Active.Export.Interval | Energy exported by EV (Wh or kWh) | |
Energy.Active.Import.Interval | Energy imported by EV (Wh or kWh) | |
Energy.Reactive.Export.Interval | Reactive energy exported by EV. (varh or kvarh) | |
Energy.Reactive.Import.Interval | Reactive energy imported by EV. (varh or kvarh) | |
Frequency | Instantaneous reading of powerline frequency | Yes |
Power.Active.Export | Instantaneous active power exported by EV. (W or KW) | |
Power.Active.Import | Instantaneous active power imported by EV. (W or KW) | Yes |
Power.Factor | Instantaneous power factor of total energy flow | Yes |
Power.Offered | Maximum power offered to EV | Yes |
Power.Reactive.Export | Instantaneous reactive power exported by EV. (var or kvar) | |
Power.Reactive.Import | Instantaneous reactive power imported by EV. (var or kvar) | |
RPM | Fan speed in RPM | Yes |
SoC | State of charge of charging vehicle in percentage | Yes |
Temperature | Temperature reading inside Charge Point. | Yes |
Voltage | Instantaneous AC RMS supply voltage | Yes |
Meter Value 'Reading Context'
Meter Values can be sent by the Charge Station at different moments.
Typically there are Meter Values at the beginning and end of a Transactions:
- Transaction.Begin
- Transaction.End
Meter Values can be sent based either:
- Sample.periodic - meter values are sent only during an active session
- Sample.Clock - meter values are sent every clock aligned interval, e.g. every 15mins, regardless of an ongoing transaction or not.
Value | Description |
Interruption.Begin | Value taken at start of interruption. |
Interruption.End | Value taken when resuming after interruption. |
Other | Value for any other situations. |
Sample.Clock | Value taken at clock aligned interval. |
Sample.Periodic | Value taken as periodic sample relative to start time of transaction. |
Transaction.Begin | Value taken at end of transaction. |
Transaction.End | Value taken at start of transaction. |
Trigger | Value taken in response to a TriggerMessage.req |